MIL-DTL-16356E
6. NOTES
(This section contains information of a general or explanatory nature that may be helpful, but is not mandatory.)
6.1 Intended use. Type A and B gauges including replacement glass sets are intended for direct boiler-water
reading on US Naval surface ships. Type C indicators, including gaskets, glass, and glass sets are intended for
boiler applications not covered by Types A and B, and direct reading tank level applications on U.S. Naval ships.
The replacement gaskets alternatives for Type C gauges are intended to allow specific materials shown on detail
drawings to be procured under this document. This document should not be used where specific gasket shape/size
and material requirements are available on separate NAVSEA drawings such as 820-5348665 for nuclear plant
applications.
6.1.1 Type A. Type A gauges are for use on main boilers and large auxiliary boilers.
6.1.2 Type B. Type B reflex gauges are for use on auxiliary boilers.
6.1.3 Type C. Type C gauges are for use on waste heat boilers requiring 150 psig flanged reflex gauges. These
gauges and welding pad designs included in Type C are used in a variety of tank-level indicating applications.
6.2 Acquisition requirements. Acquisition documents should specify the following:
a.
Title, number, and date of this specification.
b.
Type and class required (see 1.2).
c.
When first article inspection is required (see 3.1).
d.
When bolts, studs, nuts, and screws are other than specified (see 3.6).
e.
Chain requirements for sheave wheel or lever pull valves if other than as required in 3.10.2.1.
f.
When valve packing should be removed prior to shipment (3.10.5).
g.
When valve packing should be shipped separately (3.10.5).
h.
When Class B winding material is a requirement for MIL-G-24716 gaskets (3.10.5).
i.
Quantity and size of drain valves required (see 3.10.6).
j.
Visibility range required for Type A, if other than specified (see 3.12.2).
k.
Shape and dimensions for Type A, if other than specified (see 3.12.3.1).
l.
When special 22-degree bevel glass is required for size 7 glass (3.12.3.4).
m. When mica shield is not required (see 3.12.4.2).
n.
When two piece mica shield is required (3.12.4.3).
o.
When other than two gaskets are required for Class I gauges (see 3.12.5.2).
p.
Pressure rating of mounting flanges for Type A gauges, if other than specified (see 3.12.9.4).
q.
Size and visibility range of reflex glass for Type B and C gauges (see 3.13.1).
r.
Quantity, type, and size of drain valves required for Type B and C gauges (3.13.4, 3.13.8, and 3.14.7).
s.
t.
u. When specific material is identified for Type C welding pad gauges, and when welding insert bar is to be
provided (see 3.14.2).
v. When special cleanliness and detrimental material requirements apply to glass, gaskets and mica (3.14.5,
w. When level indicating plates are required (see 3.15.1).
x.
When special cleanliness is required for gauges and valves (3.17).
y.
z.
When vibration testing is required for Type B and C gauges (see 4.4.1.2).
30